Home/Standby Generator/Size Calculator

What Size Generator Do I Need?

Choose what you want powered during an outage. We add up the running watts, add the biggest starting surge, and match the total to a standby generator size [2].

Generator size calculator

Suggested standby generator size
10 kW
Running load
2,670 W
Largest starting surge
2,150 W
Peak need
4,820 W

Largest surge comes from: Sump pump (1/2 HP).

This is the smallest common air-cooled standby size that covers your peak need. On natural gas, check the generator's natural-gas rating — it's lower than the propane rating printed in the model name, so you may need the next size up.

Your running load is within reach of a large portable generator (about 7,500 running watts or more) feeding a transfer switch — a much cheaper option if you don't mind starting and refueling it by hand.

Wattages are the high end of typical ranges. Your appliances' nameplates, and a licensed electrician's load calculation, should have the final say. See installed standby generator costs.

How generators are sized

Running watts vs. starting watts. Running watts are what an appliance draws once it's on. Anything with a motor or compressor (refrigerators, pumps, air conditioners, furnace blowers) briefly pulls more when it starts. That surge typically runs 1–2 times the running wattage and lasts a fraction of a second [2].

The method. Add up the running watts of everything you want powered, then add the single largest starting wattage on top. That's your peak need. Pick a generator that exceeds it with some margin [2].

Essentials vs. whole house. Keeping the refrigerator, furnace, sump pump, lights and internet running is a modest load. Central air, an electric dryer, an electric water heater and an electric range are what push a home into the 20 kW+ range.

Hardwired loads need a transfer switch. Furnaces, well pumps and central air can't plug into a generator. A standby generator connects through an automatic transfer switch; a portable one needs a manual transfer switch or interlock installed by an electrician. Never backfeed through a dryer or wall outlet.

Run generators outside only. Portable generators belong well away from the house, never in a garage, with exhaust pointed away from windows and doors. Put battery-operated carbon monoxide alarms on every level.

Generator wattage chart

High end of typical running and starting watts, used by the calculator above [1]. A dash means no extra starting watts.

ApplianceRunning wattsStarting watts
Refrigerator4001,200
Freezer5001,000
Lights (20 LED bulbs)300—
Internet router / modem20—
Phone & laptop charging100—
TV400—
Home security system40—
CPAP (with heated humidifier)120—
Furnace blower (gas or oil furnace) (1/2 HP)8001,600
Sump pump (1/3 HP)8001,600
Sump pump (1/2 HP)1,0502,150
Well pump (1/2 HP)1,0002,000
Well pump (1 HP)2,0004,000
Central air conditioner (2 ton)2,5004,500
Central air conditioner (3 ton)3,5006,000
Central air conditioner (4 ton)5,0008,000
Window AC (10,000 BTU)1,2002,400
Space heater1,500—
Microwave1,200—
Electric range (one burner)2,400—
Dishwasher2,400—
Washing machine1,0002,300
Electric dryer6,000—
Electric water heater4,500—

Check your appliance's nameplate for its actual rating. A licensed electrician should do a load calculation before you buy a standby generator.

What will it cost?

See installed standby generator prices in your state, by size.

Standby Generator Costs →

Find a Generator Installation Pro Near You

Get free quotes from top-rated local pros. No obligation.

Sponsored — BuildCost may earn a referral fee at no extra cost to you. This site connects you with independent service professionals through a third-party matching platform.